Table 0951: Reason for Study

HL7-defined table of codes that provide additional information to the universal service identifier on why a test, study or review was ordered. Current suggested values are in support of the IHE LCC LAB-7 transaction.

Type
User-defined (site-defined)
Codes
13
Introduced
HL7 v2.9
Used in
OBR-31
THO code system
http://terminology.hl7.org/CodeSystem/v2-0951
OID
2.16.840.1.113883.18.451

User-defined (site-defined): HL7 suggests these values, and each site may use its own. PipeHat notes codes outside this list as information, not errors.

Codes

CodeMeaningDefinitionStatus
BSBank residual specimenRequests that the specimen should be stored long termN
CRConfirm results valueRequests verification of previously reported resultsN
FPStore residual specimen pending follow upRequests that the specimen should be saved for a short duration until follow up is completedN
INInterpret resultsRequests interpretation of previously reported resultsN
IRReview clinically inconsistent resultsRequests comparison of previously reported results amongst themselvesN
ITIncorrect test performedFor process improvement work this code can be used to identify when an incorrect test was performed for the target orderN
OPTest ordering problemFor process improvement work this code can be used to identify orders and the respective results, where problems occurred during orderingN
PIPatient identification problemFor process improvement work this code can be used to identify when a patient identification issue has occurred on the target orderN
SISuspected interferenceRequests verification of previously reported results due to suspected interferenceN
SPSampling problemFor process improvement work this code can be used to identify orders, where problems occurred during sample collectionretired
TPSpecimen transport problemFor process improvement work this code can be used to identify orders, where problems occurred during sample transportN
TTTurnaround time problemFor process improvement work this code can be used to identify results with excessive reporting delayN
XRIncorrect resultsFor process improvement work this code can be used to identify when incorrect result were reported for the target orderN

Where it's used

ElementNameFHIR (v2-to-FHIR mapping)
OBR-31Reason for StudyServiceRequest.reasonCode

Elements with a dot (such as CX.5) are data type components, used wherever that data type appears.

Source: HL7 Terminology (THO) 7.4.0 and the HL7 v2-to-FHIR Implementation Guide 1.0.0, published by HL7 International under CC0. Check your trading partner's specification for the values they actually send.