PipeHat Open PipeHat
HL7 V2 | TABLE 0702

Table 0702: Cycle Type

Table of codes specifying the type of cycle that is being executed. A cycle type is a specific sterilization method used for a specific type of supply item.

Type
User-defined (site-defined)
Codes
32
Introduced
HL7 v2.6
Used in
SCD-28
THO code system
http://terminology.hl7.org/CodeSystem/v2-0702
OID
2.16.840.1.113883.18.387

User-defined (site-defined): HL7 suggests these values, and each site may use its own. PipeHat notes codes outside this list as information, not errors.

Codes

CodeMeaning
FLSFlash
PRVPrevac
GRVGravity
LQDLiquid
EXPExpress
DRTDart
DRWDart Warm-up Cycle
THRThermal
ISOIsothermal
BWDBowie-Dick Test
LKTLeak Test
WFPWrap/Steam Flush Pressure Pulse (Wrap/SFPP)
SFPSteam Flush Pressure Pulse
CMWChemical Wash
PEAPeracetic Acid
EOHEO High Temperature
EOLEO Low Temperature
CRTCart Wash
UTLUtensil Wash
ISTInstrument Wash
GLSGlassware
PLAPlastic Goods Wash
ANRAnesthesia/Respiratory
GTLGentle
OPWOptional Wash
BDPBedpans
TRBTray/Basin
GNPGen. Purpose
CODCode
RNSRinse
2RSSecond Rinse
DECDecontamination

Where it's used

ElementNameFHIR (v2-to-FHIR mapping)
SCD-28—

Elements with a dot (such as CX.5) are data type components, used wherever that data type appears.

Source: HL7 Terminology (THO) 7.4.0, published by HL7 International under CC0. Check your trading partner's specification for the values they actually send.