PipeHat Open PipeHat
HL7 V2 | TABLE 0376

Table 0376: Special Handling Code

Table of codes describing how a specimen and/or container needs to be handled from the time of collection through the initiation of testing.

Type
User-defined (site-defined)
Codes
17
Introduced
HL7 v2.4
Used in
SPM-15, SAC-43, PAC-7, OM4-15
THO code system
http://terminology.hl7.org/CodeSystem/v2-0376
OID
2.16.840.1.113883.18.234

User-defined (site-defined): HL7 suggests these values, and each site may use its own. PipeHat notes codes outside this list as information, not errors.

Codes

CodeMeaning
C37Body temperature
AMBAmbient temperature
CAMBCritical ambient temperature
REFRefrigerated temperature
CREFCritical refrigerated temperature
FRZFrozen temperature
CFRZCritical frozen temperature
DFRZDeep frozen
UFRZUltra frozen
NTRLiquid nitrogen
PRTLProtect from light
CATMProtect from air
DRYDry
PSONo shock
PSADo not shake
UPRUpright
MTLFMetal Free

Where it's used

ElementNameFHIR (v2-to-FHIR mapping)
SPM-15Specimen Handling Code—
SAC-43—
PAC-7—
OM4-15—

Elements with a dot (such as CX.5) are data type components, used wherever that data type appears.

Source: HL7 Terminology (THO) 7.4.0 and the HL7 v2-to-FHIR Implementation Guide 1.0.0, published by HL7 International under CC0. Check your trading partner's specification for the values they actually send.