PipeHat Open PipeHat
HL7 V2 | TABLE 0301

Table 0301: Universal ID Type

HL7-defined table of codes specifying the type of UID (Universal Identifier). Open Issue: Table 0301 has a mix of class and instance identifiers for namespaces, which is improper. The values for instances. such as CLIA, CLIP, CAP, and NPI. These were added for pragmatic issues related to older datatypes that were universally bound tand should not be here but are needed for implementation pragmatics. These should be annotated in Comment or Usage Notes that these are not universal ID types really.

Type
HL7-defined
Codes
19
Introduced
HL7 v2.3
Used in
HD.3, EI.4
FHIR code system
http://terminology.hl7.org/CodeSystem/v2-0301
THO code system
http://terminology.hl7.org/CodeSystem/v2-0301
OID
2.16.840.1.113883.18.186

HL7-defined: The standard fixes the values. PipeHat flags codes outside this list as warnings.

Codes

CodeMeaningDefinitionFHIR codeStatus
CAPCollege of American Pathologist Accreditation NumberAllows for the ability to designate organization identifier as a "CAP" assigned number (for labs)—N
CLIAClinical Laboratory Improvement AmendmentsClinical Laboratory Improvement Amendments. Allows for the ability to designate organization identifier as a "CLIA" assigned number (for labs)CLIA
CLIPClinical laboratory Improvement ProgramClinical laboratory Improvement Program. Allows for the ability to designate organization identifier as a "CLIP" assigned number (for labs). Used by US Department of Defense.CLIP
DNSDomain Name SystemAn Internet host name, in accordance with RFC 1035; or an IP address. Either in ASCII or as integers, with periods between components ("dotted" notation).DNS
EUI64IEEE 64-bit Extended Unique IdentifierIEEE 64-bit Extended Unique Identifier is comprised of a 24-bit company identifier and a 40-bit instance identifier. The value shall be formatted as 16 ASCII HEX digits, for example, “AABBCC1122334455”. The 24-bit company identifier, formally known as Organizationally Unique Identifier (OUI-24), is guaranteed to be globally unique. The 40-bit extensions are assigned by manufacturers. This identifier is often used in equipment interfaces (e.g., “MAC” address format for IPv4 & IPv6). [See http://standards.ieee.org/regauth/oui/tutorials/EUI64.html for a detailed explanation of the format.]EUI64
GUIDglobally unique identifierSame as UUID.GUID
HCDCEN Healthcare Coding IdentifierThe CEN Healthcare Coding Scheme DesignatorHCD
HL7HL7 registration schemesHL7
ISOISO Object IdentifierAn International Standards Organization Object Identifier (OID), in accordance with ISO/IEC 8824. Formatted as decimal digits separated by periods; recommended limit of 64 charactersISO
LLocalThese are reserved for locally defined coding schemes.—
L,M,NLocalThese are reserved for locally defined coding schemes.L,M,Ndeprecated
MLocalThese are reserved for locally defined coding schemes.—
NLocalThese are reserved for locally defined coding schemes.—
NPIUS National Provider IdentifierAllows for the ability to designate organization identifier as a "NPI" assigned number (lab, any medical provider, can be a person or an organization)—N
RandomRandomUsually a base64 encoded string of random bits.<p>Note: Random IDs are typically used for instance identifiers, rather than an identifier of an Assigning Authority that issues instance identifiersRandom
URIUniform Resource IdentifierURI
UUIDUniversal Unique IdentifierThe DCE Universal Unique Identifier, in accordance with RFC 4122. Recommended format is 32 hexadecimal digits separated by hyphens, in the digit grouping 8-4-4-4-12UUID
x400X.400 MHS identifierAn X.400 MHS identifier. Recommended format is in accordance with RFC 1649x400
x500X500 directory NameAn X.500 directory namex500

FHIR codes from the HL7 v2-to-FHIR concept map UniversalIDType (unconditional mappings only).

Where it's used

ElementNameFHIR (v2-to-FHIR mapping)
HD.3Universal ID Type—
EI.4Universal ID Type—

Elements with a dot (such as CX.5) are data type components, used wherever that data type appears.

Source: HL7 Terminology (THO) 7.4.0 and the HL7 v2-to-FHIR Implementation Guide 1.0.0, published by HL7 International under CC0. Check your trading partner's specification for the values they actually send.